High performance bidirectional module, automatic control
Two-way flow between the vehicle and the power station, free charging and discharging
Real-time monitoring and adjusting charging and discharging strategies
Adapt to multiple BMS protocols and serve different brand vehicles
| Charging mode parameters | |||
| Rated output power | 80kW | ||
| Grid side voltage | 380Vac±15%(Three phase) | ||
| Grid frequency | 50Hz±5Hz | ||
| DC side output voltage | 200~750Vdc | ||
| Constant power range | 400~750Vdc | ||
| DC side output current | Single gun maximum 200A | ||
| Inverter mode parameters | |||
| Rated output power | 80kW | ||
| DC side input voltage | 200~750Vdc | ||
| Grid side voltage | 380Vac(Three phase) | ||
| Grid frequency | 50Hz±5Hz | ||
| system parameter | |||
| THDI | <5%(Full load) | ||
| Power factor | ±-0.99(Full load) | ||
| Productiveness | ≥95%(Full load) | ||
| Wiring mode | 3P3W | ||
| noise | ≤65 dB | ||
| Cooling method | forced air cooling | ||
| Power distribution | Support | ||
| Number of charging guns | Single gun, double gun | ||
| Protection level | IP54 | ||
| Communication interface | Ethernet, 4G | ||
| Display | 7-inch touch screen | ||
| DC output characteristics | |||
| Output voltage range | 200 V~750 V | ||
| Output current range | Single gun maximum 200A | ||
| Voltage stabilization accuracy | Not more than ± 0.5% (stabilized state, input voltage AC 323 V to 456 V, output voltage 200 V to 750 V, output current 0 to rated current value) | ||
| Steady current accuracy | Not more than ± 1% (steady current state, input voltage AC 323 V to 456 V, output voltage 200 V to 750 V, output current 20% of rated current to rated current value) | ||
| Voltage ripple factor | Not more than 1% (in stable state, the input voltage is AC 323 V to 456 V, the output voltage is 200 V to 750 V, and the output current is 0 to the rated current value) | ||
| Output voltage setting error | Not more than ± 0.5% (stabilized state, output voltage 200 V to 750 V) | ||
| Output current setting error | Not exceeding ± 0.3 A (set output DC current < 30 A)< br /> Not more than ± 1% (steady current state, set output DC current ≥ 30 A) | ||
| Voltage limiting characteristics | During steady current operation, when the DC output voltage exceeds the set value, the automatic limit output voltage increases and switches to steady state | ||
| Current limiting characteristics | During steady state operation, when the DC output current exceeds the set value, the automatic limit output current increases and changes to steady state | ||
| Maximum efficiency | ≥95% | ||
| Protection features: input overvoltage and undervoltage protection, input overcurrent protection, output overvoltage and undervoltage protection, overtemperature protection, etc | |||