Intelligent battery detection system
Intelligent battery detection system
Intelligent battery detection system
Intelligent battery detection system
  • One machine with three functions, combining charging, feedback load, and battery detection
  • Test the entire vehicle without disassembling the battery and changing the control strategy
  • High reliable protection performance
  • Modular design, easy to expand
  • Wide operating temperature range: - 40 ℃~75 ℃
  • Wide range of DC side voltage: 200Vdc~750Vdc
  • Soft switching design, low loss, high efficiency
Intelligent battery detection system
Intelligent battery detection system
Intelligent battery detection system

Technical Parameter

Charging mode parameters
Rated output power 80kW
Grid side voltage 380Vac±15%(Three phase)
Grid frequency 50Hz±5Hz
DC side output voltage 200~750Vdc
Constant power range 400~750Vdc
DC side output current Maximum 200A
Discharge mode parameters
Rated output power 80kW (input: 400~750Vdc)
DC side input voltage 200~750Vdc
Grid side voltage 380Vac(Three phase)
Grid frequency 50Hz±5Hz
System parameter
THDI <5%(Full load)
Power factor ±-0.99(Full load)
Productiveness ≥95%(Full load)
Wiring Mode 3P3W
Noise ≤65 dB
Cooling method Forced air cooling
Power distribution support
Number of charging guns Single gun
Protection level IP54
communication interface Ethernet, 4G
Display 7-inch touch screen
Charger Cable 5m
DC output characteristics
Output voltage range 200 V~750 V
Output current range Maximum 200A
Output voltage measurement error Not more than ± 0.1% (Steady state, input voltage AC 323 V to 456 V, output voltage 200 V to 750 V, output current 0 to rated current value)
Output current measurement error Not more than ± 0.1% (steady current state, input voltage AC 323 V to 456 V, output voltage 200 V to 750 V, output current 20% of rated current to rated current value)
Voltage ripple factor Not more than 1% (in stable state, the input voltage is AC 323 V to 456 V, the output voltage is 200 V to 750 V, and the output current is 0 to the rated current value)
Output voltage setting error Not more than ± 0.5% (stabilized state, output voltage 200 V to 750 V)
Output current setting error Not exceeding ± 0.3 A (set output DC current < 30 A);
Not more than ± 1% (steady current state, set output DC current ≥ 30 A)
Temperature measurement error ±0.5℃
Time measurement error ±0.1s
Insulation accuracy ±5%
Protection features: input overvoltage and undervoltage protection, input overcurrent protection, output overvoltage and undervoltage protection, overtemperature protection, etc