240kW/360kW/480kW split type DC charging pile
240kW/360kW/480kW split type DC charging pile
240kW/360kW/480kW split type DC charging pile
240kW/360kW/480kW split type DC charging pile
  • Modular design with strong error tolerance
  • One pile with multiple guns and multiple channels for simultaneous charging
  • Intelligent and flexible power allocation for maximum efficiency
  • High reliability, multi-directional safety protection
  • Remote control, maintenance, diagnosis
240kW/360kW/480kW split type DC charging pile
240kW/360kW/480kW split type DC charging pile
240kW/360kW/480kW split type DC charging pile

Technical Parameter

Split 6-gun charging stack
Equipment model JWE-D1000-480K
Rated power KW 480(Downward compatible)
AC input voltage V AC380V ± 20%, three-phase five-wire system
AC power frequency Hz 50±5%
Input power factor 20-50% load, > 0.97; 50~100% load, > 0.99
Rated output voltage V DC 200~1000 continuously adjustable
Output current range A 0~250A continuously adjustable per gun
Dual gun power distribution Support power support; Charging a car with two guns
Single gun output power range KW 0-180 Adjust output power according to BMS requirements
BMS auxiliary power supply 12V/24V configurable
Voltage accuracy Not more than ± 0.5%
Current accuracy ≥ 30A: no more than ± 1% < 30A: no more than ± 0.3A
Voltage stabilization accuracy Not greater than ± 0.5%
Steady current accuracy Not greater than ± 0.5%
Ripple coefficient Effective value: no more than ± 0.5% Peak value: no more than ± 1%
Current sharing imbalance ≤5%
Input impulse current A ≤ 110% of rated input current
Output overshoot voltage V ≤ 110% steady-state output voltage
Productiveness ≥95%
Power Factor ≥0.99APFC
Noise dB ≤65
Oscillating wave immunity level 3(1MHz 和 100kHz)
Protection level IP55 outdoor all-in-one machine
MTBF ≥87600h
Display 7-inch touch screen
Ambient temperature -30℃—+75℃
Height <2000m Derating over 2000m
Humidity 5%—95%
Output side detection and alarm Battery disconnection and reverse connection judgment function, pile end insulation detection function, short circuit alarm function, DC contactor adhesion detection and alarm function