120kW/160kW integrated DC charging pile
120kW/160kW integrated DC charging pile
120kW/160kW integrated DC charging pile
120kW/160kW integrated DC charging pile
  • Modular design with strong error tolerance
  • High reliability, multi-directional safety protection
  • One double gun, synchronous charging
  • Remote control, maintenance, diagnosis
120kW/160kW integrated DC charging pile
120kW/160kW integrated DC charging pile
120kW/160kW integrated DC charging pile

Technical Parameter

Equipment model JWE-D750-360K
Rated power KW 360 (backward compatible)
AC input voltage V AC380V ± 20%, three-phase five-wire system
AC power frequency Hz 50±5%
Input power factor   20-50% load, > 0.97; 50~100% load, > 0.99
Rated output voltage V DC 200~1000 continuously adjustable
Output current range A Each gun is continuously adjustable from 0 to 250A 
Dual gun power distribution   Support power support; Charging a car with two guns
Single gun output power range KW 0~187.5 Adjust output power according to BMS requirements
BMS auxiliary power supply   12V/24V configurable
Voltage accuracy   Not more than ± 0.5%
Current accuracy   ≥ 30A: no more than ± 1% < 30A: no more than ± 0.3A
Voltage stabilization accuracy   Not greater than ± 0.5%
Steady current accuracy   Not greater than ± 0.5%
Ripple coefficient   Effective value: no more than ± 0.5% Peak value: no more than ± 1%
Current sharing imbalance   ≤5%
Input impulse current A ≤ 110% of rated input current
Output overshoot voltage V ≤ 110% steady-state output voltage
Productiveness   ≥95%
Power factor   ≥0.99APFC
noise dB ≤65
Oscillating wave immunity   Level 3(1MHz和100kHz)
Protection level   IP54 outdoor all-in-one machine
MTBF   ≥87600h
display   7-inch touch screen
ambient temperature   -30℃—+75℃
height   <2000m Derating over 2000m
humidity   5%—95%
Output side detection and alarm   Battery disconnection and reverse connection judgment function, pile end insulation detection function, short circuit alarm function, DC contactor adhesion detection and alarm function
Electrostatic discharge immunity   Level 3
Immunity to radio frequency electromagnetic field radiation   Level 3
Electrical Fast Transient Burst Immunity   Level 3
Surge (impact) immunity   Level 3
Immunity to conducted disturbances induced by radio frequency fields   Level 3
Power frequency magnetic field immunity   Level 4
Damped oscillatory magnetic field immunity   Level 4
Harmonic current limit requirements (THD)   ≤ 5% (Class A equipment)
Communication interface   Configure Ethernet/4G
Payment method   Support card payment, Alipay, WeChat, APP and other payment methods
Dimensions (width * depth * height) mm 700*400*1900